4%off DEHN MAKE VAP COMBINED ARRESTER SINGLE-PHASE TT SYSTEMS 900361

DEHN MAKE VAP COMBINED ARRESTER SINGLE-PHASE TT SYSTEMS 900361

Brand:
Supplier Name N/A
Product Code: DEHN DVA CSP 1P 50 FM
Availability: In Stock
Rs.13,200 Rs.12,723
Check Your Pincode
Brand : DEHN Product Name : VAP COMBINED ARRESTER SINGLE-PHASE TT SYSTEMS It applies to the base station 230V single-phase TT and TN systems (1 + 1 circuit) modular composite lightning current surge protector. WITH REMOTE MONITORING Nominal AC voltage (UN) 230 V (50/ 60 Hz) Continuous operating ac voltage [LN] (UC) 255 V (50/60 Hz) Lightning impulse current (10/350 μs) [L + N -PE] (Itotal) 50 kA Lightning impulse current (10/350 μs) [LN] / [N-PE] (Iimp) 25 kA Nominal discharge current (8/20 μs) [LN] / [N-PE] (In) 25/50 kA Voltage protection level [LN] / [N-PE ] (UP) ≤ 1.5 / ≤ 1.5 kV Follow current extinguishing capability [LN] / [N-PE ] (Ifi) 50 kArms / 100 Arms Freewheeling / Selectivity expected continued flow 50 kArms, 20A fuse does not jump Response time (tA) ≤ 100 ns IK = 50 kArms, maximum backup fuse (L) 315 A gL / gG Maximum backup fuse (L-L ') 125 A gL / gG TOV characteristics (UT) [LN] 440 V / 120 min tolerance TOV characteristics (UT) [N-PE] 1200 V / 200 ms tolerance Operating temperature range parallel / series (TU) -40 ° C ... +80 ° C / -40 ° C ... +60 ° C Job status / fault indication green / red Ports 1 Minimum Cross-sectional area (L, L ', N, N', PE, 9) (min.) 10 mm2 A single strand of wire / cord Maximum Cross-sectional area (L, N, PE) ( max.) 50 mm2 Stranded / 35 mm2 Flexible wire Maximum Cross-sectional area (L ', N', 9 ) (max.) 35 mm2 stranded / 25 mm2 flexible wire Mounting 35 mm DIN rail according to EN 60715 Housing material red thermoplastic, UL 94 V-0 Installation Location Indoor Degree of protection IP 20 Size 4 mods, DIN 43880 Certification KEMA, VDE, UL, VdS Remote signaling contact floating changeover contact Switching capacity ac 250 V / 0,5 A DC switching capacity of 250 V / 0.1 A; 125 V / 0.2 A; 75 V / 0.5 A The maximum cross-sectional area for remote signaling terminals 1.5 mm2 A single strand of wire / cord Additional technical parameters for the expected short-circuit current of 50 kArms distribution equipment (through VDE tested) - The maximum prospective short-circuit current 100 kArms (220 kApeak) - Ability to inhibit the main circuit freewheeling / interdiction capacity 100 kArms (220 kApeak) IK = maximum backup fuse 100kArms when 315 A gL / gG Weight 664 g

Write a review

Note: HTML is not translated!
Bad           Good